GENERAL INFORMATION
 
 
 
 
 
 
 
  | ARTICLE  | Am. J. innov. res. appl. sci. Volume 14,  Issue 2, Pages 1-8 (February, 2022)
   Research Article 1
|
| HOME || ABOUT US  || ARCHIVES || AIMS AND SCOP || AUTHORS || REVIEW|| SUBMIT MANUSCRIPT || EDITORIAL BOARD |
| IMPACT FACTOR AND INDEXING | | PUBLICATION FEE | | CONTACT US |
| Info-AJIRAS-® Journal ISSN 2429-5396 (Online) / Reference  CIF/15/0289M |
  American Journal of Innovative Research & Applied Sciences
|
American Journal of innovative
Research & Applied Sciences 
ISSN  2429-5396 (Online)
OCLC Number: 920041286
Authors Contact

*Correspondant author and authors Copyright © 2022:

| Biva Rani Mondal 1* | Mashud Parvez 2 *| Kishor Chandra paul 3 | Lotifur Rahman 3 | and | Waqer Ahmed Khan 4 |


Affiliation.

1. Assistant Professor | Department of Clinical Pathology | Bangladesh Shishu Hospital and Institute | Dhaka |
2. Associate Professor of Histopathology | Department of Pathology | Bangladesh Shishu Hospital and Institute| Dhaka |
3.Medical Technologist | Department of Clinical Pathology | Bangladesh Shishu Hospital and Institute | Dhaka |
4. Professor of Pathology (Retired) | Bangladesh Shishu Hospital and Institute | Dhaka |

This article is made freely available as part of this journal's Open Access: ID | Mondal-Ref01-ajira1221222 | 
| FEBRUARY | VOLUME 14 | ISSUE N° 2 | 2022 |
Double click to edit
RESUME

Contexte : La mesure par spectrométrie gamma avec le système CZT500s nécessite des étalonnages en énergie et en efficacité, en utilisant des sources de rayonnement gamma de référence ou étalons. Idéalement, cet étalon doit être ponctuel, mais, dans la pratique, toute source a une dimension finie. Le problème est alors de chercher une configuration géométrique qui permet de faire une approximation quasi-ponctuelle des sources étalons
. Objectif : Développer une méthode permettant de faire l’étalonnage en efficacité du système CZT500s avec une source d’Iode-131 non ponctuelle, mais considérée comme quasi-ponctuelle sous certaine configuration géométrique.  Méthode : Evaluer les débits mesurés en présence de la source d’Iode-131 à différentes distances, variant de 10 cm à 350 cm, avec le débitmètre IdentiFinder et tracer la courbe distance-débit de dose. A partir du terme source, qui n’est applicable que pour une source ponctuelle à 1m du détecteur, calculer le débit à cette distance en fonction de l’activité connue de l’iode-131. Utiliser ce débit comme référence et calculer les débits correspondant de 10 cm à 350 cm en utilisant le modèle de variation du débit de dose en fonction de l’inverse carré de la distance. Utiliser les tests statistiques sur les résidus et sur les valeurs aberrantes pour déterminer la distance à partir de laquelle on peut considérer la source comme quasi-ponctuelle. Finalement, utiliser la distance de 1m, pour les déterminations de l’efficacité et de l’activité. Résultats : Les résultats sont comparables à partir de 20 cm. La source d’Iode-131 non ponctuelle peut être considérée comme ponctuelle à partir de cette distance, si on utilise l’IdentiFinder. L’efficacité du détecteur CZT 500s placée à 1 mètre dE la source considérée comme ponctuelle décroit en fonction de l’énergie, elle est maximale pour les gammas d’énergie environ 200 KeV. Conclusion : On retrouve les mêmes résultats par comparaison visuelle. Cependant, avoir des références quantitatives assure mieux la validité et la fiabilité des tests. Un programme a été conçu pour le graphe de la courbe d’efficacité et faire le calcul de l’activité. Finalement, la transformation du débit de dose en activité est réalisée dans les conditions de l’expérience.
Mots-clés: 131-I, Spectrométrie Gamma, CZT-500s, Etalonnage en efficacité, Dosimétrie

ABSTRACT

Context: Measurement by gamma spectrometry with the CZT500s system associated with an MCA166 requires energy and efficiency calibrations, using reference gamma radiation sources or standards. Ideally, this standard should be punctual, but in practice any source has a finite dimension. The problem is then to find a geometrical configuration, which allows making a quasi-punctual approximation of the standard sources. Objective: To develop a method for performing the efficiency calibration of a CZT500s detector system with a non-point Iodine-131 source, which can be considered as quasi-punctual under certain geometric configuration. Method: Assess the dose rates measured in the presence of the Iodine-131 source at various distances, varying from 10 cm to 350 cm, using the IdentiFinder and plot the distance-dose rate curve. From the source term, which is only applicable for a point source at 1m from the detector, calculate the dose rate at this distance according to the Iodine-131 known activity. Use this dose rate as a reference and calculate the corresponding dose rates from 10 cm to 350 cm, using the dose rate variation model as a function of the square inverse of the distance. Use statistical tests on the residuals and on the outliers to determine the distance from which the source can be considered as quasi-punctual. Finally, use the distance of 1m, a prerequisite for the use of the source term, for the efficiency and activity determinations. Résultats : Les résultats sont comparables à partir de 20 cm. La source d’Iode-131 non ponctuelle peut être considérée comme ponctuelle à partir de cette distance, si on utilise l’IdentiFinder. L’efficacité du détecteur CZT 500s placée à 1 mètre dE la source considérée comme ponctuelle décroit en fonction de l’énergie, elle est maximale pour les gammas d’énergie environ 200 KeV. Conclusion : On retrouve les mêmes résultats par comparaison visuelle. Cependant, avoir des références quantitatives assure mieux la validité et la fiabilité des tests. Un programme a été conçu pour le graphe de la courbe d’efficacité et faire le calcul de l’activité. Finalement, la transformation du débit de dose en activité est réalisée dans les conditions de l’expérience.

Mots-clés: 131-I, Spectrométrie Gamma, CZT-500s, Etalonnage en efficacité, Dosimétrie
COMPARISON OF SOME HEMATOLOGICAL VALUES BETWEEN COVID-19 POSITIVE AND NEGATIVE CHILDREN

| Biva Rani Mondal 1* | Mashud Parvez 2 *| Kishor Chandra paul 3 | Lotifur Rahman 3 | and | Waqer Ahmed Khan 4 |.  Am. J. innov. res. appl. sci.  2022; 14(2):1-8.

    | PDF FULL TEXT |                      | Abstract and Author Contact |                          | XML FILE  |
| HOME | ABOUT US | ARCHIVE | AIMS AND SCOP | AUTHORS | REVIEW | SUMIBMIT MANUSCRIPT | EDITORIAL BOARED | PUBLICATION FEE |
| ISSN: 2429-5396 (e) | https://www.american-jiras.com |                                                                                      |
|
Web Site Form: v 0.1.05 | JF 22 Cours, Wellington le Clairval, Lillebonne | France  |